Banner Image

Test Directory

Lactate Dehydrogenase Isoenzymes

Test Summary

Diagnostic aid for myocardial infarction. Also for malignancies, anemias, and acute liver and muscle injury.

Aliases

  • N/A

Specimen Collection

Special Instructions

N/A

Preferred Specimen

2 mL serum

Minimum Volume

1 mL

Instructions

Total Lactate Dehydrogenase results should be supplied by Client.
Centrifuge serum specimens within 1 hour of collection, transfer serum to a clean, plastic, screw-capped vial(s), and send at room temperature to the laboratory. Do not refrigerate or freeze specimens. Specimens cannot be shared, and no other tests should be ordered with Lactate Dehydrogenase Isoenzymes.

Patient Preparation

N/A

Storage

N/A

Transport Temperature

Room temperature

Specimen Stability

  • Room temperature: 7 days
  • Refrigerated: Unacceptable
  • Frozen: Unacceptable

Limitations

N/A

Other Acceptable Specimens

N/A

Unacceptable Specimens

Hemolysis • Received refrigerated • Received frozen

Order Code

LDHISO

EPIC (Premier) Code

LAB632

Includes

LD1, LD2, LD3, LD4, LD5

CPT Code

  • 83625

Billing Code

  • 700000

CPT Statement

Methodology

Electrophoresis

FDA Status

FDA Approved

Physician Attestation of Informed Consent

N/A

Testing Laboratory

Quest Diagnostics Nichols Institute
14225 Newbrook Drive
Chantilly VA, 20153

Reference Range

LD 1 19-38 %
LD 2 30-43 %
LD 3 16-26 %
LD 4 3-12 %
LD 5 3-14 %

Setup Schedule / Expected Turnaround Time

Monday, Wednesday, Friday morning Report available: 1 day

Specimen Collection

Special Instructions

N/A

Preferred Specimen

2 mL serum

Minimum Volume

1 mL

Instructions

Total Lactate Dehydrogenase results should be supplied by Client.
Centrifuge serum specimens within 1 hour of collection, transfer serum to a clean, plastic, screw-capped vial(s), and send at room temperature to the laboratory. Do not refrigerate or freeze specimens. Specimens cannot be shared, and no other tests should be ordered with Lactate Dehydrogenase Isoenzymes.

Patient Preparation

N/A

Storage

N/A

Transport Temperature

Room temperature

Specimen Stability

  • Room temperature: 7 days
  • Refrigerated: Unacceptable
  • Frozen: Unacceptable

Limitations

N/A

Other Acceptable Specimens

N/A

Unacceptable Specimens

Hemolysis • Received refrigerated • Received frozen

Billing

CPT Code

  • 83625

Billing Code

  • 700000

CPT Statement

Result Information

Methodology

Electrophoresis

Testing Laboratory

N/A

Reference Range

LD 1 19-38 %
LD 2 30-43 %
LD 3 16-26 %
LD 4 3-12 %
LD 5 3-14 %

Setup Schedule / Expected Turnaround Time

Monday, Wednesday, Friday morning Report available: 1 day