Lambda Light Chain, Free
Test Summary
Aids in the diagnosis and monitoring of multiple myeloma, lymphocytic neoplasms, Waldenstrom's Macroglobulinemia and connective tissue diseases such as Systemic Lupus Erythematosus.
Aliases
- N/A
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1.0 mL serum
Minimum Volume
0.5 mL
Instructions
Barrier tubes (serum separator tubes) are preferred. If non-barrier tubes are utilized, the serum must be removed immediately after centrifuging and placed in a screw-cap transfer tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Refrigerated
Specimen Stability
- Room Temperature = N/A
- Refrigerated = 7 days
- Frozen = At least 7 days
Limitations
N/A
Other Acceptable Specimens
N/A
Unacceptable Specimens
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.
Order Code
LAMBDA
EPIC (Premier) Code
LAB3212
Includes
N/A
CPT Code
- 83521
Billing Code
- 500000
CPT Statement
Methodology
Immunoturbidimetric Assay
FDA Status
Approved
Physician Attestation of Informed Consent
N/A
Testing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439
2308 Sandridge Drive
Moraine OH, 45439
Reference Range
N/A
Setup Schedule / Expected Turnaround Time
Monday - Friday; BS; Report available 1 - 3 days
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1.0 mL serum
Minimum Volume
0.5 mL
Instructions
Barrier tubes (serum separator tubes) are preferred. If non-barrier tubes are utilized, the serum must be removed immediately after centrifuging and placed in a screw-cap transfer tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Refrigerated
Specimen Stability
- Room Temperature = N/A
- Refrigerated = 7 days
- Frozen = At least 7 days
Limitations
N/A
Other Acceptable Specimens
N/A
Unacceptable Specimens
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.
Result Information
Methodology
Immunoturbidimetric Assay
Testing Laboratory
N/A
Reference Range
N/A
Setup Schedule / Expected Turnaround Time
Monday - Friday; BS; Report available 1 - 3 days