Banner Image

Test Directory

CBC (Complete Blood Count)

Test Summary

Examination of the numerical and/or morphological findings of the complete blood count by the physician are useful in the diagnosis of disease states such as anemias, leukemias, allergic reactions, viral, bacterial, and parasitic infections.

Aliases

  • CBC w/o Diff
  • CBC
  • Blood Count
  • Complete Blood Count

Specimen Collection

Special Instructions

N/A

Preferred Specimen

3 mL or 4 mL whole blood K2EDTA (lavender top) tube(s) or K2EDTA (Microtainer® lavender top) tube(s). 

Minimum Volume

Minimum fill 1 mL (Microtainer® filled between the 2 lines).

Instructions

Avoid hemolysis. Gently invert K2EDTA Lavender top tube 10 times immediately at time of blood collection.

Patient Preparation

N/A

Storage

K2EDTA (lavender top) tube

Transport Temperature

Refrigerated

Specimen Stability

  • Room Temperature = 24 hours
  • Refrigerated = 48 hours
  • Any questions see Hematology Tech Specialists before rejecting

Limitations

N/A

Other Acceptable Specimens

N/A

Unacceptable Specimens

Rejected for gross hemolysis, clotted, <1 mL, non-K2EDTA tube type, >48 hours old, frozen.  Any questions see Hematology Tech Specialists before rejecting. 

Order Code

CBC

EPIC (Premier) Code

LAB118

Includes

Hematocrit; Hemoglobin; MCH; MCHC; MCV; RDW; red blood cell count (RBC); platelet count; white blood cell count (WBC)

CPT Code

  • 85027

Billing Code

  • 300430

CPT Statement

Methodology

Automated Cell Counter

FDA Status

FDA approved

Physician Attestation of Informed Consent

N/A

Testing Laboratory

CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439

Department

Hematology

Reference Range

See Report

Setup Schedule / Expected Turnaround Time

Sunday - Saturday; HE; Report available: 1 day

Specimen Collection

Special Instructions

N/A

Preferred Specimen

3 mL or 4 mL whole blood K2EDTA (lavender top) tube(s) or K2EDTA (Microtainer® lavender top) tube(s). 

Minimum Volume

Minimum fill 1 mL (Microtainer® filled between the 2 lines).

Instructions

Avoid hemolysis. Gently invert K2EDTA Lavender top tube 10 times immediately at time of blood collection.

Patient Preparation

N/A

Storage

K2EDTA (lavender top) tube

Transport Temperature

Refrigerated

Specimen Stability

  • Room Temperature = 24 hours
  • Refrigerated = 48 hours
  • Any questions see Hematology Tech Specialists before rejecting

Limitations

N/A

Other Acceptable Specimens

N/A

Unacceptable Specimens

Rejected for gross hemolysis, clotted, <1 mL, non-K2EDTA tube type, >48 hours old, frozen.  Any questions see Hematology Tech Specialists before rejecting. 

Billing

CPT Code

  • 85027

Billing Code

  • 300430

CPT Statement

Result Information

Methodology

Automated Cell Counter

Testing Laboratory

N/A

Reference Range

See Report

Setup Schedule / Expected Turnaround Time

Sunday - Saturday; HE; Report available: 1 day