Banner Image

Test Directory

Protein Electrophoresis, Serum

Test Summary

Serum protein electrophoresis (SPE) is an analytical technique that provides separation of serum protein into six fractions: Albumin, Alpha-1, Alpha-2, Beta-1, Beta-2, and Gamma. Interpretation of elevation, decreased, or visual change in different fractions can be used as a diagnostic aid for a variety of different disease states and protein abnormalities, including monoclonal gammopathies

Aliases

  • Protein, Total and Protein Electrophoresis (Serum), PEP (Serum), PRO ELEC (Serum), SPE, SPEP

Specimen Collection

Special Instructions

N/A

Preferred Specimen

1 mL serum

Minimum Volume

1 mL

Instructions

Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.

Patient Preparation

N/A

Storage

Original tube preferred, may be sent in a screw-top transfer tube.

Transport Temperature

Refrigerated

Specimen Stability

  • Room Temperature = 3 days
  • Refrigerated = 10 days
  • Frozen = 2 months

Limitations

N/A

Other Acceptable Specimens

N/A

Unacceptable Specimens

Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.

Order Code

SPE

EPIC (Premier) Code

LAB345

Includes

Includes Total Protein

CPT Code

  • 84155
  • 84165

Billing Code

  • 300362
  • 300366

CPT Statement

Methodology

electrophoresis

FDA Status

FDA Approved

Physician Attestation of Informed Consent

N/A

Testing Laboratory

CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439

Department

Chemistry

Reference Range

See Report

Setup Schedule / Expected Turnaround Time

Monday - Friday; Report available: 2 - 3 days

Specimen Collection

Special Instructions

N/A

Preferred Specimen

1 mL serum

Minimum Volume

1 mL

Instructions

Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.

Patient Preparation

N/A

Storage

Original tube preferred, may be sent in a screw-top transfer tube.

Transport Temperature

Refrigerated

Specimen Stability

  • Room Temperature = 3 days
  • Refrigerated = 10 days
  • Frozen = 2 months

Limitations

N/A

Other Acceptable Specimens

N/A

Unacceptable Specimens

Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.

Billing

CPT Code

  • 84155
  • 84165

Billing Code

  • 300362
  • 300366

CPT Statement

Result Information

Methodology

electrophoresis

Testing Laboratory

N/A

Reference Range

See Report

Setup Schedule / Expected Turnaround Time

Monday - Friday; Report available: 2 - 3 days