Rheumatoid Factor
Test Summary
RF may be elevated in multiple conditions: SLE, rheumatoid arthritis, scleroderma, Sjögren's Syndrome, leprosy, tuberculosis, syphilis, malignancy, thyroid disease and in a significant percentage of otherwise normal elderly patients.
Aliases
- RA
- RA Factor
- RA Factors
- RA Latex
- RA, Quantitative
- RF
- RF (Rheumatoid Factor)
- Rheumatoid Arthritis Titer
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1 mL serum
Minimum Volume
1 mL
Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Refrigerated
Specimen Stability
- Room Temperature = 1 day
- Refrigerated = 8 days
- Frozen = 3 months
Limitations
N/A
Other Acceptable Specimens
Plasma from Lithium Heparin (Light Green Top) tube
Unacceptable Specimens
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.
Order Code
RF
EPIC (Premier) Code
LAB356
Includes
N/A
CPT Code
- 86431
Billing Code
- 300000
CPT Statement
Methodology
Immunoturbidimetric Assay
FDA Status
FDA Approved
Physician Attestation of Informed Consent
N/A
Testing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439
2308 Sandridge Drive
Moraine OH, 45439
Reference Range
<14 IU/mL
Setup Schedule / Expected Turnaround Time
24/7; Report available: Daily
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1 mL serum
Minimum Volume
1 mL
Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Refrigerated
Specimen Stability
- Room Temperature = 1 day
- Refrigerated = 8 days
- Frozen = 3 months
Limitations
N/A
Other Acceptable Specimens
Plasma from Lithium Heparin (Light Green Top) tube
Unacceptable Specimens
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.
Result Information
Methodology
Immunoturbidimetric Assay
Testing Laboratory
N/A
Reference Range
<14 IU/mL
Setup Schedule / Expected Turnaround Time
24/7; Report available: Daily