Glucose
Test Summary
Plasma glucose levels may be abnormally high (hyperglycemia) or abnormally low (hypoglycemia). Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolic disorders including diabetes mellitus, idiopathic hypoglycemia, and pancreatic islet cell neoplasm.
Aliases
- RBS (R Indicates Random)
- Random Blood Sugar
- Serum GLucose
- Fasting Blood Sugar (S)
- Fasting Glucose (P)
- Fasting Glucose (S)
- Glucose
- Glucose (P)
- 1 Hour Post Prandial
- 1 Hour PP
- 1
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1 mL serum
Minimum Volume
1 mL
Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
CLEARLY label each tube with the Time and Hour of collection.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
CLEARLY label each tube with the Time and Hour of collection.
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Room Temperature or Refrigerated
Specimen Stability
- Room Temperature = 5 days
- Refrigerated = 5 days
- Frozen = n/a
Limitations
N/A
Other Acceptable Specimens
Plasma from Lithium Heparin (Light Green Top) tube
Unacceptable Specimens
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.
Order Code
GLUB
EPIC (Premier) Code
LAB218
Includes
N/A
CPT Code
- 82947
Billing Code
- 300000
CPT Statement
Methodology
Spectrophotometry (SP)
FDA Status
FDA Approved
Physician Attestation of Informed Consent
N/A
Testing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439
2308 Sandridge Drive
Moraine OH, 45439
Reference Range
See Sample Report
Setup Schedule / Expected Turnaround Time
24/7; Report available: Daily
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1 mL serum
Minimum Volume
1 mL
Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
CLEARLY label each tube with the Time and Hour of collection.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.
Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
CLEARLY label each tube with the Time and Hour of collection.
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Room Temperature or Refrigerated
Specimen Stability
- Room Temperature = 5 days
- Refrigerated = 5 days
- Frozen = n/a
Limitations
N/A
Other Acceptable Specimens
Plasma from Lithium Heparin (Light Green Top) tube
Unacceptable Specimens
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.
Result Information
Methodology
Spectrophotometry (SP)
Testing Laboratory
N/A
Reference Range
See Sample Report
Setup Schedule / Expected Turnaround Time
24/7; Report available: Daily