Banner Image

Test Directory

Direct LDL

Test Summary

LDL cholesterol is a key factor in the pathogenesis of atherosclerosis and Coronary Artery Disease (CAD), while HDL cholesterol has often been observed to have a protective effect. Even within the normal range of total cholesterol concentrations, an increase in LDL cholesterol can produce an associated increased risk for CAD. LDL cholesterol binds to receptor sites on macrophages in blood vessel walls inciting several changes to the blood wall which enhance atherosclerotic plaque development.

Aliases

  • DLDL
  • LDL Direct
  • LDL (comment
  • Only if ordered alone with no other tests on requisition)

Specimen Collection

Special Instructions

N/A

Preferred Specimen

1 mL serum

Minimum Volume

1 mL

Instructions

Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.

Patient Preparation

N/A

Storage

Original tube preferred, may be sent in a screw-top transfer tube.

Transport Temperature

Room Temperature or Refrigerated

Specimen Stability

  • Room Temperature = N/A
  • Refrigerated = 7 days
  • Frozen = 12 months

Limitations

N/A

Other Acceptable Specimens

Plasma from Lithium Heparin (Light Green Top) tube

Unacceptable Specimens

Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.

Order Code

DLDL

EPIC (Premier) Code

LAB919

Includes

N/A

CPT Code

  • 83721

Billing Code

  • 300300

CPT Statement

Methodology

Spectrophotometry (SP)

FDA Status

FDA Approved

Physician Attestation of Informed Consent

N/A

Testing Laboratory

CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439

Department

Chemistry

Reference Range

See Report

Setup Schedule / Expected Turnaround Time

24/7; Report available: Daily

Specimen Collection

Special Instructions

N/A

Preferred Specimen

1 mL serum

Minimum Volume

1 mL

Instructions

Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.

Patient Preparation

N/A

Storage

Original tube preferred, may be sent in a screw-top transfer tube.

Transport Temperature

Room Temperature or Refrigerated

Specimen Stability

  • Room Temperature = N/A
  • Refrigerated = 7 days
  • Frozen = 12 months

Limitations

N/A

Other Acceptable Specimens

Plasma from Lithium Heparin (Light Green Top) tube

Unacceptable Specimens

Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.

Billing

CPT Code

  • 83721

Billing Code

  • 300300

CPT Statement

Result Information

Methodology

Spectrophotometry (SP)

Testing Laboratory

N/A

Reference Range

See Report

Setup Schedule / Expected Turnaround Time

24/7; Report available: Daily