Cortisol Baseline Response
Order Code: CORTB
Test Summary
Cortisol is increased in Cushing's Disease and decreased in Addison's Disease (adrenal insufficiency).
Aliases
- Cortisol Level
- Cortisone
- Hydrocortisone
- Hydroxycorisone
- Cortisol (serum)
- Cortisol Level (serum)
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1 mL serum
Minimum Volume
1 mL
Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered. Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered. Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Refrigerated
Specimen Stability
- Room temperature = 24 hours
- Refrigerated = 4 days
- Frozen = 12 months
Limitations
N/A
Other Acceptable Specimens
Plasma from Lithium Heparin (Light Green Top) tube
Unacceptable Specimens
- Hemolysis
- Lipemia
- Incorrect specimen type
- Insufficient sample volume
- Improper storage conditions
- Exceeds specimen stability guidelines
- Contaminated sample
Order Code
CORTB
EPIC (Premier) Code
LAB814
Includes
N/A
CPT Code
- 82533
Billing Code
- 300203
CPT Statement
Methodology
Immunoassay (IA)
FDA Status
FDA Approved
Physician Attestation of Informed Consent
N/A
Testing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439
2308 Sandridge Drive
Moraine OH, 45439
Department
Chemistry
Reference Range
See Report
Setup Schedule / Expected Turnaround Time
24/7; Report available: Within 1 day of set up
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1 mL serum
Minimum Volume
1 mL
Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered. Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered. Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Refrigerated
Specimen Stability
- Room temperature = 24 hours
- Refrigerated = 4 days
- Frozen = 12 months
Limitations
N/A
Other Acceptable Specimens
Plasma from Lithium Heparin (Light Green Top) tube
Unacceptable Specimens
- Hemolysis
- Lipemia
- Incorrect specimen type
- Insufficient sample volume
- Improper storage conditions
- Exceeds specimen stability guidelines
- Contaminated sample
Result Information
Methodology
Immunoassay (IA)
Testing Laboratory
N/A
Reference Range
See Report
Setup Schedule / Expected Turnaround Time
24/7; Report available: Within 1 day of set up