Cortisol 30 Minute Response
Test Summary
Cortisol is increased in Cushing's Disease and decreased in Addison's Disease (adrenal insufficiency).
Aliases
- Cortisol level
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1 mL serum
Minimum Volume
1 mL
Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred.
Red top serum unacceptable for testing.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered. Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube."
Red top serum unacceptable for testing.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered. Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube."
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Refrigerated
Specimen Stability
- Room temperature = 24 hours
- Refrigerated = 4 days
- Frozen = 12 months
Limitations
N/A
Other Acceptable Specimens
Plasma from Lithium Heparin (Light Green Top) tube
Unacceptable Specimens
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.
Order Code
CORT30
EPIC (Premier) Code
LAB811
Includes
N/A
CPT Code
- 82533
Billing Code
- 300203
CPT Statement
Methodology
Immunoassay (IA)
FDA Status
FDA Approved
Physician Attestation of Informed Consent
N/A
Testing Laboratory
CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439
2308 Sandridge Drive
Moraine OH, 45439
Department
Chemistry
Reference Range
See Report
Setup Schedule / Expected Turnaround Time
24/7; Report available: Daily
Specimen Collection
Special Instructions
N/A
Preferred Specimen
1 mL serum
Minimum Volume
1 mL
Instructions
Barrier tubes (serum separator tubes or plasma separator tubes) are preferred.
Red top serum unacceptable for testing.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered. Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube."
Red top serum unacceptable for testing.
Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered. Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube."
Patient Preparation
N/A
Storage
Original tube preferred, may be sent in a screw-top transfer tube.
Transport Temperature
Refrigerated
Specimen Stability
- Room temperature = 24 hours
- Refrigerated = 4 days
- Frozen = 12 months
Limitations
N/A
Other Acceptable Specimens
Plasma from Lithium Heparin (Light Green Top) tube
Unacceptable Specimens
Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.
Result Information
Methodology
Immunoassay (IA)
Testing Laboratory
N/A
Reference Range
See Report
Setup Schedule / Expected Turnaround Time
24/7; Report available: Daily