Banner Image

Test Directory

Comprehensive Metabolic Panel

Test Summary

See Individual Tests

Aliases

  • SMA-CMP, CMP 14, Comp Metabolic Panel (14), CMET, CMP, CMP WITH EGFR, Comp Met , Comp Metabolic,

Specimen Collection

Special Instructions

N/A

Preferred Specimen

1 mL serum

Minimum Volume

1 mL

Instructions

Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.

Patient Preparation

N/A

Storage

Original tube preferred, may be sent in a screw-top transfer tube.

Transport Temperature

Room Temperature or Refrigerated

Specimen Stability

  • Refrigerated: 48 hours
  • See individual components for additional details

Limitations

N/A

Other Acceptable Specimens

Plasma from Lithium Heparin (Light Green Top) tube

Unacceptable Specimens

Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.

Order Code

CMP

EPIC (Premier) Code

LAB120

Includes

Includes: Albumin, Albumin/Globulin Ratio (calculated), Alkaline Phosphatase, ALT, AST, BUN/Creatinine Ratio (calculated), Calcium, Carbon Dioxide, Chloride, Creatinine with GFR Estimated, Globulin (calculated), Glucose, Potassium, Sodium, Total Bilirubin, Total Protein, Urea Nitrogen(BUN)

CPT Code

  • 80053

Billing Code

  • 300069

CPT Statement

Methodology

See individual tests

FDA Status

FDA Approved

Physician Attestation of Informed Consent

N/A

Testing Laboratory

CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439

Department

Chemistry

Reference Range

See Report

Setup Schedule / Expected Turnaround Time

24/7; Report available: Daily

Specimen Collection

Special Instructions

N/A

Preferred Specimen

1 mL serum

Minimum Volume

1 mL

Instructions

Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.

Patient Preparation

N/A

Storage

Original tube preferred, may be sent in a screw-top transfer tube.

Transport Temperature

Room Temperature or Refrigerated

Specimen Stability

  • Refrigerated: 48 hours
  • See individual components for additional details

Limitations

N/A

Other Acceptable Specimens

Plasma from Lithium Heparin (Light Green Top) tube

Unacceptable Specimens

Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.

Billing

CPT Code

  • 80053

Billing Code

  • 300069

CPT Statement

Result Information

Methodology

See individual tests

Testing Laboratory

N/A

Reference Range

See Report

Setup Schedule / Expected Turnaround Time

24/7; Report available: Daily