Banner Image

Test Directory

Beta-2-Microglobulin

Test Summary

Beta-2-microglobulin normally passes through the glomerulus into the proximal tubule where much of it is reabsorbed. Serum levels are therefore an index of glomerular function. When impaired, serum levels rise in inverse ratio to glomerular filtration rate. Increased amounts of beta-2-microglobulin are excreted in several renal disorders, e.g., Balkan nephropathy, heavy metal poisoning and renal tubular disease due to therapeutic agents. Serial levels of beta-2-microglobulin in serum and urine are used to evaluate transplant viability and anticipate rejection. Following a successful graft, serum levels decline toward normal. Increasing serum levels provide an early sign of rejection. Elevated levels are also noted in lymphoproliferative disorders, neoplasms (malignant and benign), inflammatory disease, and autoimmune diseases such as systemic lupus erythematosus (SLE) and Sjögren's disease.

Aliases

  • B2-MIC
  • Microglobulin
  • Beta2

Specimen Collection

Special Instructions

N/A

Preferred Specimen

1 mL serum

Minimum Volume

1 mL

Instructions

Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.

Patient Preparation

N/A

Storage

Original tube preferred, may be sent in a screw-top transfer tube.

Transport Temperature

Refrigerated

Specimen Stability

  • Room Temperature = 3 days
  • Refrigerated = 3 days
  • Frozen = 6 months

Limitations

N/A

Other Acceptable Specimens

Plasma from Lithium Heparin (Light Green Top) tube

Unacceptable Specimens

Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.

Order Code

B2MC

EPIC (Premier) Code

LAB067

Includes

N/A

CPT Code

  • 82232

Billing Code

  • 300163

CPT Statement

Methodology

Immunoassay (IA)

FDA Status

FDA Approved

Physician Attestation of Informed Consent

N/A

Testing Laboratory

CompuNet Clinical Laboratories, LLC
2308 Sandridge Drive
Moraine OH, 45439

Department

Chemistry

Reference Range

<2.51 mg/L

Setup Schedule / Expected Turnaround Time

24/7; Report available: Daily

Specimen Collection

Special Instructions

N/A

Preferred Specimen

1 mL serum

Minimum Volume

1 mL

Instructions

Barrier tubes (serum separator tubes or plasma separator tubes) are preferred. If non-barrier tubes are utilized, the serum/plasma must be removed immediately after centrifuging and placed in a screw-cap transfer tube.

Collection notes: Avoid hemolysis. Invert tubes at least 8 times. Allow to clot in an upright position for 30 minutes. Within 2 hours, centrifuge tubes 10 minutes. Keep tightly stoppered.

Do NOT re-centrifuge tubes. Do NOT freeze the primary collection tube.

Patient Preparation

N/A

Storage

Original tube preferred, may be sent in a screw-top transfer tube.

Transport Temperature

Refrigerated

Specimen Stability

  • Room Temperature = 3 days
  • Refrigerated = 3 days
  • Frozen = 6 months

Limitations

N/A

Other Acceptable Specimens

Plasma from Lithium Heparin (Light Green Top) tube

Unacceptable Specimens

Hemolysis, Lipemia, incorrect specimen type, insufficient sample volume, improper storage conditions, exceeds specimen stability guidelines, contaminated sample.

Billing

CPT Code

  • 82232

Billing Code

  • 300163

CPT Statement

Result Information

Methodology

Immunoassay (IA)

Testing Laboratory

N/A

Reference Range

<2.51 mg/L

Setup Schedule / Expected Turnaround Time

24/7; Report available: Daily